Apparatus | Temperature (°C) | Time | Shaking rate | References |
---|---|---|---|---|
Barnstead Thermolyne Big Bill orbital shaker | – | 2 h | 150 rpm | Petts et al. (2017) |
Rotary shaker | 20–25 | 30 min | 150 rpm | Pauzan et al. (2013) |
Four-blade 1-inch mixer and a Talboys light-duty mixer overhead | 25 | 30 min | 500 rpm | Do and Sabatini (2011) |
PMC Data Plate digital hot plate/stirrer | 20 | 45 min | 1000 rpm | Tuntiwiwattanapun et al. (2013) |
Shaker Cole-Parmer Ping-PongTM | 25 | 45 min | 200 horizontal oscillations/min | Kadioglu et al. (2011) |
Cole-Parmer Ping-Pong horizontal shaker | – | 30 min | 300 rpm | Do et al. (2014a, b) |
Horizontal Shaker Ping-PongTM | 25 | 20 min | 100–150 shakes/min | Do and Sabatini (2010) |
Horizontal thermo shaker | 60 | 30 min | 185 rpm | Ramly et al. (2017) |
Mechanical shaking | 23 | 1 h | 200 rpm | Nguyen et al. (2010) |
Screw capped plastic centrifuge tubes | 60 | 1 h | – | Radi et al. (2013) |
Shaker SHA-C | 80 | 1 h | 160 rpm | Chen et al. (2018) |
HH-2 digital thermostatic water bath + TA-2 programmed coagulating stirrer | 80 | 30 min | 250 rpm | Qin et al. (2015) |
Tergi-O-Tometer | 10–20 | 3 cycles: 20 min, 3 min, and 2 min | 120 rpm | Do et al. (2014a, b), Phaodee et al. (2019) and Phan et al. (2010a, b) |